A Brandt company - serving Fresno, CA

Before & After Gallery - Brandt HVAC Co Fresno

AC repairAC repair
Furnace & heatingFurnace & heating
Heat pumpsHeat pumps
Ductless mini splitsDuctless mini splits
CarrierCarrier
TraneTrane
GoodmanGoodman
Every visit starts with

Seasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed

Your new heating and cooling system for as low as$119/month*On approved credit; ask for current terms

Diagnosis first, numbers second - you approve the repair price before a single part goes in.

Get your free estimate

HVAC Before & After in Fresno, CA

We can describe a tricky install or a cramped attic retrofit all day, but the honest truth is this: seeing the work speaks louder than any claim we could type. The photos below show real HVAC conditions we’ve walked into around Fresno, and what we left behind. No stock images, no staged workbenches. Just the kind of before-and-after evidence we’d want to see before trusting a crew in our own home. Each project gets a short write-up so you know what you’re looking at.

Call (559) 354-6878

Explore

Styles & brands we work with

AC repair
AC repair
Furnace & heating
Furnace & heating
Heat pumps
Heat pumps
Ductless mini splits
Ductless mini splits
Carrier
Carrier
Trane
Trane
Goodman
Goodman

Recent Transformations

Capacitor Failure on a 100-Degree Day

BeforeBeforeAfterAfter
Before: swollen, leaking dual-run capacitor pulled from a Carrier condenser in the Tower District.
BeforeBeforeAfterAfter
After: new dual-run capacitor installed, terminals cleaned, amperage draw verified.

The homeowner heard a faint buzzing at the condenser and then nothing. Inside temps climbed past 90 by noon. We found a swollen, leaking capacitor that had finally shorted. We replaced it with an OEM-specced part, cleaned the contactor, and verified the compressor amp draw before leaving. Total time on site: just under an hour. The house was cooling again before the afternoon peak.

Furnace Flame Sensor Caked in Carbon

BeforeBeforeAfterAfter
Before: flame sensor coated in carbon buildup on a Goodman furnace near Woodward Park.
HVAC technician performing professional air conditioning repair and maintenance service
After: flame sensor cleaned, microamp reading confirmed within manufacturer spec.

This Goodman furnace would light, run for three seconds, then shut down. Classic flame sensor failure. Carbon buildup on the sensor rod was blocking the microamp signal the board needs to confirm ignition. We pulled the sensor, cleaned it properly, and tested the reading. The furnace stayed lit through a full cycle. The written guarantee on this repair covers the same failure for 365 days.

Refrigerant Leak Repair and Recharge

HVAC technician testing an air conditioner capacitor with a multimeter
Before: oil residue at a brazed line joint, the telltale sign of a slow refrigerant leak.
Two HVAC technicians installing an outdoor air conditioning unit.
After: joint repaired, nitrogen pressure-tested, vacuum pulled, system recharged to factory charge weight.

A homeowner in the Fig Garden area noticed the AC running constantly but the house never got below 78. We found oil staining at a line joint near the evaporator coil, indicating a slow refrigerant leak. After repairing the joint, we pressure-tested with nitrogen, pulled a proper vacuum, and recharged the system to the exact factory charge weight on the Lennox data plate. This is the kind of repair where skipping the leak test saves an hour but costs a compressor later. We don’t skip it.

Dirty Evaporator Coil Choking Airflow

HVAC technician performing professional furnace repair and venting installation
Before: evaporator coil fouled with a layer of dust, dander, and hair inside a Rheem air handler.
HVAC technician repairing a residential furnace unit
After: coil cleaned, condensate line flushed, static pressure checked across the return and supply.

This Rheem system near Clovis was freezing up at the coil every afternoon. The evaporator was so packed with debris that airflow had dropped low enough to ice the coil solid. We pulled the panel, cleaned the coil without damaging the fins, flushed the condensate line, and measured static pressure to confirm the restriction was gone. The homeowner told us the system had never blown this strong. In a lot of cases, “needs more refrigerant” actually means “needs a coil cleaning.”

AC Tune-Up and Condenser Refresh

HVAC technician performing furnace repair and electrical diagnostics on a residential unit.
Before: condenser coil matted with cottonwood, dirt, and grass clippings on a Trane unit in Sunnyside.
HVAC technician performing professional air conditioning system maintenance and repair
After: coils washed, fins combed where flattened, capacitor tested, refrigerant pressures checked.

This Trane condenser sits near a row of cottonwoods that shed every spring. By July, the coil was a solid mat. The system ran hot, the compressor was cycling on its high-pressure limit, and the electric bill showed it. We performed a full maintenance service: coil wash, fin combing, capacitor test, contactor inspection, refrigerant pressure check, and a written report of everything we found. The compressor discharge temp dropped 22 degrees. That’s the difference between a unit that limps through August and one that runs clean.

Blower Motor Replacement in a Tight Attic

HVAC technician inspecting a residential air conditioning filter in the ceiling
Before: seized blower motor out of a York air handler in a low-clearance attic near Tower District.
HVAC technician performing professional air conditioning maintenance and diagnostics
After: new blower motor installed, wheel balanced, amp draw confirmed within rating.

The homeowner heard a hum for about a week, then nothing. No airflow at all. We pulled the old motor out of a genuinely awful attic space, matched it with the correct replacement, and installed the new motor with a balanced wheel. Amp draw was verified below the nameplate rating, and the system was quieter than the homeowner remembered it ever being. Written price was agreed before we touched a single wire, same as always.

Want Results Like These?

Every project above started the same way: a homeowner called us, we showed up, looked at the actual equipment, and wrote the price down before any work began. No pressure, no surprises. If you’ve got an AC or furnace acting up in Fresno, call (559) 354-6878 and talk to a live person. We’ll get you on the schedule and give you the same straight answers.

Written by Devin Marlowe, Owner at Brandt HVAC Co Fresno, serving Fresno since 2003.

Before & after

See the difference

Before - Recent ProjectBeforeAfter - Recent ProjectAfter
Recent Project
Before - Full RestorationBeforeAfter - Full RestorationAfter
Full Restoration
Before - Complete UpgradeBeforeAfter - Complete UpgradeAfter
Complete Upgrade
Need HVAC help in Fresno? Licensed & insured · 60-minute response · free estimates
Call (559) 354-6878
Local Service Coverage

Request a Free Estimate in Fresno

Tell us what you need - Brandt HVAC Co Fresno responds fast. No obligation.

By clicking submit, you agree to the terms of our Privacy Policy and consent to receive communications by call, text, or email regarding your project, including by the service partners who may complete the work.

Prefer to text? Text Now
Call Now - 24/7 Dispatch